PERKUATAN GESER KOLOM BETON BERTULANGBERPENAMPANG PERSEGI DENGAN KAWAT KASA METODEMORTAR JACKETING BERPENAMPANG BULAT
DOI:
https://doi.org/10.21831/inersia.v8i1.3700Abstract
ABSTRACTColum reinforcement is essential in a structure. When a column is weak, itwill cause total failure to the structure. This study examined the behavior of columnreinforced with mortar jacketing method and wire netting. The objective of this studywas to identify the contribution of the reinforcement to the shear strength and columnductility. Four column specimens were made. They consisted of one original column(as comparison) in square shape of 150 x 150 mm, and 700 mm height andfoundation plate in 1200 x 700 mm with 250 mm thickness and three specimens insame dimensions and strengthened by mortar jacketing to become column withround section in 220 mm diameter and 730 mm height. Longitudinal reinforcementand wire netting in 1.7 mm diameter and consisted of small squares of 25 mm x 25mm with 1 layer strengthening (KP-1). Two layers (KP-2), and 3 layers (KP-3) wereused as the mortar jacketing. Sika Grout 215 New was used as the filler. Loadingtype used was constant axial and cyclic lateral to simulate earthquake by using thedisplacement control method. The results showed that in KP-1, KP-2 and KP-3reinforced column, their lateral load capacities increased by 90.263%, 101.985%,124.196%, respectively, than the average original column (KA-1). Addition of wirenetting for KP-1, KP-2, and KP-3 showed general increase of displacement at amaximum lateral load in compare to the original column (KA-1). Drift ratio atmaximum load at KA-1 was 2.07%. As for KP-1dan KP-3, the maximum loadswere 2.52 % and 2.924%, respectively. However, the drift ratio of KP-2 was1.192%, or smaller than 1.50%. The stiffness values obtained from the testsfor KA-1, KP-1, KP-2 and KP-3 were 3.92 KN/mm, 9.04 KN/mm, 9.01kN/mm,and 8.14kN/mm, respectively. Ductility factor (μ) of KA-1, KP-1, KP-2, and KP-3were 5.451, 6.273, 3.938, and 6.667, respectively. Thus, more netting wire showedincreasing ductility, except for KP-2 which had the smallest ductility in compare toother specimens. Based on the test results and the regulation of ACI 374.1-05.200,the reinforced column could be used for structures with maximum R (responsemodification factor) of 6.Keywords : Shear collapse, Mortar jacketing, netting wire, cyclic loadDownloads
Published
2012-05-01
How to Cite
dan Suprapto Siswosukarto (2), D. E. W. (1), A. T. (2),. (2012). PERKUATAN GESER KOLOM BETON BERTULANGBERPENAMPANG PERSEGI DENGAN KAWAT KASA METODEMORTAR JACKETING BERPENAMPANG BULAT. Inersia : Jurnal Teknik Sipil Dan Arsitektur, 8(1). https://doi.org/10.21831/inersia.v8i1.3700
Issue
Section
Articles
License
Authors who publish with INERSIA journal agree to the following terms:
- Authors retain copyright and grant the INERSIA journal right of first publication with the work simultaneously licensed under Creative Commons Attribution License (CC BY 4.0) that allows others to share the work with an acknowledgment of the work's authorship and initial publication in this journal.
- Authors can enter into separate, additional contractual arrangements for the non-exclusive distribution of the published version of the work (e.g., post it to an institutional repository or edit it in a book), with an acknowledgment of its initial publication in this journal.
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) before and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work.

INERSIA by https://journal.uny.ac.id/index.php/inersia was distributed under a Creative Commons Attribution 4.0 International License